Mass serological screening in the Armed Forces involves detecting serological markers of chronic infections, particularly viral hepatitis B and C, syphilis, and HIV among young military recruits. The objective of this study is to evaluate the analytical performance of the chemiluminescence technique (CMIA-Architect i2000 SR) in mass serological screening using the serum-pooling method at the virology laboratory of the Mohammed V Military Teaching Hospital.


Samples with known serological results (positive/negative) were grouped into pools of different sizes (2, 5, 10, and 15 sera). These pools were tested using chemiluminescence (CMIA-Architect i2000 SR). A cost analysis was conducted to assess potential savings based on seroprevalence and pool size.


Results showed that the pooling method maintained 100% specificity. Overall sensitivities for detecting positive samples were 93.1% for HBV, 83.33% for HCV, and 86.36% for HIV. Positive and negative predictive values were high for all three viral markers, highlighting the reliability of the pooling method. Additionally, this approach generated significant cost savings, ranging from 46% to 80%. 


Conclusion: This study demonstrated the solid analytical performance of the chemiluminescence technique (CMIA-Architect i 2000 SR) using the serum-pooling method for detecting HBV, HCV, and HIV serological markers in low-seroprevalence regions.

Article Details

R, A., O, A., S, H. S., N, C., S, O., H, G., … IA, L. (2025). Mass Serological Screening in the Armed Forces Using the Serum-Pooling Method. Analytical Evaluation of the Chemiluminescence Method. International Journal of Clinical Virology, 9(1), 001–006. https://doi.org/10.29328/journal.ijcv.1001062
Research Articles

Copyright (c) 2025 Abi R, et al.

Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

Abdalhamid B, Bilder CR, McCutchen EL, Hinrichs SH, Koepsell SA, Iwen PC. Assessment of specimen pooling to conserve SARS CoV-2 testing resources. Am J Clin Pathol. 2020;153(6):715-718. Available from: https://doi.org/10.1093/ajcp/aqaa064

Dorfman R. The detection of defective members of large populations. Ann Math Statist. 1943;14(4):436-440. Available from: https://www.medicine.mcgill.ca/epidemiology/hanley/bios601/Likelihood/Dorfman1943PooledTests.pdf.

Cunningham R, Northwood JL, Kelly CD, Boxall EH, Andrews NJ. Routine antenatal screening for hepatitis B using pooled sera: validation and review of 10 years experience. J Clin Pathol. 1998;51(5):392-395. Available from: https://doi.org/10.1136/jcp.51.5.392

Novack L, Sarov B, Goldman-Levi R, Yahalom V, Safi J, Soliman H, et al. Impact of pooling on accuracy of hepatitis B virus surface antigen screening of blood donations. Trans R Soc Trop Med Hyg. 2008;102(8):787-792. Available from: https://doi.org/10.1016/j.trstmh.2008.04.005

Dinesha TR, Boobalan J, Sivamalar S, Subashini D, Solomon SS, Murugavel KG, et al. Occult HBV infection in HIV-infected adults and evaluation of pooled NAT for HBV. J Viral Hepat. 2018;25(6):718-723. Available from: https://doi.org/10.1111/jvh.12858

Liu P, Shi Z, Zhang Y, Xu Z, Shu H, Zhang X. A prospective study of a serum-pooling strategy in screening blood donors for antibody to hepatitis C virus. Transfusion. 1997;37(7):732-736. Available from: https://doi.org/10.1046/j.1537-2995.1997.37797369450.x

Rabenau H, Schütz R, Berger A, Doerr HW, Weber B. How accurate is serologic testing of plasma pools for hepatitis B virus surface antigen, anti-human immunodeficiency virus 1 and 2, and anti-hepatitis C virus? Transfus Med Hemother. 1996;23(3):124-130. Available from: https://doi.org/10.1159/000223281

Emmanuel JC, Bassett MT, Smith HJ, Jacobs JA. Pooling of sera for human immunodeficiency virus (HIV) testing: an economical method for use in developing countries. J Clin Pathol. 1988;41(5):582-585. Available from: https://doi.org/10.1136/jcp.41.5.582

McMahon EJ, Fang C, Layug L, Sandler SG. Pooling blood donor samples to reduce the cost of HIV-1 antibody testing. Vox Sang. 1995;68(4):215-219. Available from: https://doi.org/10.1111/j.1423-0410.1995.tb02575.x

Saleh RM, Farouk AM, Anani M, Attia FM. Validation of specimen pooling versus individual samples for screening of viral markers and syphilis in blood bag strategy: Single-center study. Egypt J Hosp Med. 2023;90:757-762. Available from: https://doi.org/10.21608/ejhm.2023.279928